E-11
(RS-422)
Pin No. Signal Signal Name Direction
1 RXA Receive Data (+) Input
2 RXB Receive Data (-) Input
3 TXA Send Data (+) Output
4 NC No Connection -
5 GND Ground -
6 NC No Connection -
7 TXB Send Data (-) Output
8 NC No Connection -
9 NC No Connection -
FG FG Frame Ground -
(RS-485)
Pin No. Signal Signal Name Direction
1 DATE+ Send/Receive Data (+) In/Output
2 DATE- Send/Receive Data (-) In/Output
3 NC No Connection -
4 NC No Connection -
5 GND Ground -
6 NC No Connection -
7 NC No Connection -
8 NC No Connection -
9 NC No Connection -
FG FG Frame Ground -
Be sure to connect pin number 5 (SG) of COM1 to the host unit's
Signal Ground terminal.
Be sure to confirm what settings will be used by the other
device and set the dip switches accordingly. Failure to do so can
result in a unit malfunction or damage.
Whenever changing the PS-A switches, be sure to first turn the
PS-A's power supply OFF. Failure to do so can cause a PS-A
malfunction.
Connect the FG terminal line to the connector cover's PS-A con-
nector attachment screw.
FG and SG terminals are internally connected in the PS-A. When
connecting to another device, be sure to create an SG shorting
loop in your system.
Use inch type (#4-40UNC) threads to hold the cable's set (attachment) screws